- Obtain all keys to be programmed.
- Using programmed key 1, proceed as follows :
- Inser key into ignition switch for at least 1 second.
- Remove key.
- Repeat following procedure 5 times : Insert key into ignition switch for a maximum of 1 second, then remove it.
- Ensure immobilizer waning lamp illuminates on last insert.
- Remove key.
- Using programmed key 2, preceed as follows :
- Turn ignition switch ON.
- Ensure immobilizer warning lamp remains illuminated for approx. 2 seconds.
- Switch ignition OFF.
- Remove key.
- Using new key preceed as follows :
- Trun ignition switch ON.
- Ensure immobilizer warning lamp remains illuminated for approx. 2 seconds.
- Switch ignition OFF.
- Remove key.
To exit programming mode : Wait 30 seconds.
Note : A maximum of 8 keys can be programmed. Keys can also be programmed using diagnostic equipment.