[REMOTE] Hilux TGN16/GGN15(25)/KUN16(26) Remote programming

Wireles door control transmitter registration procedure(Fujitsu TEN)

Preconditions :

  • No Key in ignition key cylinder.
  • Driver's door is opened.(Other doors are closed)
Procedure :
  1. Insert key into ignition key cylinder, then remove it. 
  2. Insert key into ignition key cylinder, then remove it within 5 sec.
  3. Close and Open driver's door 2 times and insert key into ignition key cylinder, then remove it within 20 sec.
  4. Close and Open driver's door 2 times insert key into ignition key cylinder and close all doors within 25 sec.
  5. Turn ignition switch from LOCK to ON and back to LOCK at approx. 1 sec intervals according to the number of times shown below.
    • Number of ON-LOCK operations of ignition switch :
      • Add mode : 1 times
      • Rewrite mode : 2 times
      • Confirmation mode : 3 times
      • Prohibition mode : 5 times 
    • If the number of the ON-LOCK operations of the ignition switch is 0, 4 or 6 or more, there will be no response(Door lock and unlock operation)t to show which mode is been selected.
    • This step must be operate within 35 sec. 
  6. Remove key from ignition key cylinder within 5 sec.
  7. Response to selected mode(Door lock operation) :
    • Body ECU automatically performs door LOCK-UNLOCK operation to show which mode has beem selected.
      • Add mode/Rewrite mode : 1~2 times
      • Confirmation mode : 1~5 times
      • Prohibition mode : 5 times
    • Note :
      • In the confirmation mode, when LOCK-UNLOCK operation is performed 2 times, the number of registered recognition codes is 2.
      • In the Confirmation mode, when 0 codes are registered, LOCK-UNLOCK operation is automatically performed 5 times.
      • Confirmation mode and Prohibition mode is complete in this step.
  8. Press LOCK and UNLOCK switches on transmitter 3 sec or more within 40 sec.
  9. Press either one of the tow switches on transmitter.
  10. Response to registration completion :
    • Body ECU automatically performs door LOCK-UNLOCK operation to show whether registration has been completed correctly or not within 3 sec.
      • LOCK-UNLOCK 1 times : Success
      • LOCK-UNLOCK 2 times : Failed
    • When LOCK-UNLOCK operation is performed 2 times, registration of recognition code has failed. Perform registration procedures from beginning once again.
    • If other transmitter is to be registered, repeat step 8 within 40 sec.
  11. Perform either of the following :
    • Open driver's door.
    • 40 sec elapses since the door control relay response.
    • Insert key into ignition key cylinder.
    • Four types of recognition code are registered at one time.
  12. Complete

No comments: